Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Hip & Pelvis ; : 23-32, 2019.
Article in English | WPRIM | ID: wpr-740450

ABSTRACT

PURPOSE: Isolated greater trochanteric (GT) fractures are often identified using plain radiography of patients with post-traumatic hip pain. In many cases, the fracture extends to form an occult intertrochanteric fracture. We conducted a study to determine the frequency of occult intertrochanteric fractures in patients diagnosed with isolated GT fractures using plain radiographs. MATERIALS AND METHODS: Among 3,017 individuals who visited our emergency department with a trauma-induced pertrochanteric femur fracture between July 2004 and March 2018, 100 patients diagnosed with isolated GT fractures using plain radiographs were retrospectively analyzed. Patients were divided into two groups, those with: i) isolated GT fractures (group A) and ii) occult intertrochanteric fractures (group B). In addition, plain radiographs, magnetic resonance imaging results, and treatment methods were further analyzed in each group. If surgery treatment was needed, it was performed by one surgeon, and in all cases, a 2-hole dynamic hip screw was used. RESULTS: Among the 100 cases of isolated GT fractures diagnosed using plain radiograph, additional examinations revealed that 10 (10.0%) were suffering from isolated GT fractures alone, while the remaining 90 (90.0%) were further diagnosed with occult intertrochanteric fracture. Gender, age, mechanism of injury, and bone mineral density did not correlate with fracture type. CONCLUSION: In our analysis, 90% of injuries initially diagnosed as isolated GT fractures were found to extend into occult intertrochanteric fractures upon further examination with additional imaging modalities. Therefore, additional evaluation should be performed to test for the potential presence of occult intertrochanteric fractures and to establish appropriate treatment plans.


Subject(s)
Humans , Bone Density , Emergency Service, Hospital , Femur , Fractures, Closed , Hip , Hip Fractures , Magnetic Resonance Imaging , Radiography , Retrospective Studies
2.
The Journal of the Korean Orthopaedic Association ; : 419-427, 2017.
Article in Korean | WPRIM | ID: wpr-655102

ABSTRACT

PURPOSE: The purpose of current study is to evaluate the midterm results of cementless primary total hip arthroplasty (THA) using a dual offset titanium tapered stem. MATERIALS AND METHODS: A retrospective analysis of 102 cases (84 patients), with a minimum of 7-year clinical follow-up, was performed. All of the cases consisted of patients who underwent primary cementless THA, using a dual offset titanium tapered stem in The Catholic University of Korea, Bucheon St. Mary's Hospital between July 2004 and May 2009. Clinical results were analyzed via the Harris hip score, level of thigh pain, squeaking around hip joint, and complication rate. Radiologic results were examined with stability and location of inserted prosthesis, hypertrophy of femoral cortex, and osteolysis. RESULTS: Out of the 102 cases (84 patients; 47 males and 37 females), with the mean age of 55.9 years (range, 27–79 years) and mean follow-up period of 99.2 months (range, 84–132 months). The mean Harris hip score was 53.8 preoperatively (range, 26–75) and improved to 93.5 postoperatively (range, 74–100) (p=0.000). All of the cases gained stable bony fixation on the final follow-up, including 2 cases of intra-operative proximal femur fracture. Calcar remodeling was observed in 94 cases, however, they were irrelevant with stem stability. Cortical hypertrophy of femur was seen in 12 cases and thigh pain in 4 cases; nonetheless, they were not relevant (p=0.067). There was 1 case of squeaking sound during joint movement. Hip dislocation occurred in 1 case early after the procedure, but the event was due to excessive anteversion of the acetabular cup, in which a revisional replacement procedure of the acetabular cup was conducted. No sign of ceramic breakage was observed. There were 2 cases of heterotrophic ossification. CONCLUSION: Results from a 7-year follow-up of cementless THA using dual offset titanium tapered stem were encouraging in both clinical and radiologic evaluations.


Subject(s)
Humans , Male , Acetabulum , Arthroplasty, Replacement, Hip , Ceramics , Femur , Follow-Up Studies , Hip , Hip Dislocation , Hip Joint , Hypertrophy , Joints , Korea , Osteolysis , Prostheses and Implants , Retrospective Studies , Thigh , Titanium
3.
Journal of the Korean Fracture Society ; : 192-199, 2016.
Article in Korean | WPRIM | ID: wpr-73234

ABSTRACT

PURPOSE: The purpose of this study is to evaluate the postoperative outcomes of elderly patients with stable 2-part intertrochanteric femur fractures surgically treated using dynamic hip screw with 2-hole side plate. MATERIALS AND METHODS: From February 2008 to January 2014, 50 patients older than the age of 65 years, who had been followed-up for more than 6 months after the operation at The Catholic University of Korea, Bucheon St. Mary's Hospital were enrolled. A clinical evaluation of the skin incision length, operating time, and ambulatory status, using Clawson's Ambulation Capacity Classification, was performed, and a radiologic evaluation of Fogagnolo reduction quality, tip-apex distance (TAD), Cleveland index, sliding extent of lag screws, time duration till bony union, and complications was also done. RESULTS: The mean skin incision length was 9.8 cm (range, 8-13 cm), the mean operating time was 41.4 minutes (range, 30-60 minutes), and 32 patients recovered their ambulatory function. Forty-eight patients gained bony union, and the time lapsed till union was average 10.6 weeks (range, 8-16 weeks). The evaluation of postoperative radiologic images showed the following reduction statuses by the Fogagnolo classification: 46 cases of "Good", 3 cases of "Acceptable," and 1 case of "Poor." Moreover, the mean TAD was 18.9 mm (range, 9.0-24.9 mm). While 45 cases fit into the zone 5 of the Cleveland index, other 3 were within zone 8 and the other 2 were within zone 6. The mean sliding length of the lag screws were 4.9 mm (range, 0.1-19.4 mm). There were a case of nonunion and a case of periprosthetic infection with nonunion as complications. CONCLUSION: Using dynamic hip screws with 2-hole side plate for stable 2-part intertrochanteric femur fractures in elderly patients showed satisfactory results with respect to the recovery of ambulatory functions and bony union.


Subject(s)
Aged , Humans , Classification , Femur , Hip Fractures , Hip , Korea , Skin , Walking
SELECTION OF CITATIONS
SEARCH DETAIL